JAI TMC-4200GE User Manual Page 80

  • Download
  • Add to my manuals
  • Print
  • Page
    / 92
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 79
Page 68
TM-4200GE Hardware
Operation
9.3.7 PWC PIV Mode
The PWC PIV is based on PIV Fixed Exposure. In this mode, the first time exposure is controlled by the
pulse width of the external trigger, which is similar to PWC mode. The real exposure time of the first
image is equal to the pulse width of the external trigger.
The maximum trigger frequency in this mode is equal to 1/ (transfer time of two frames + exposure time
of the first image).
The minimum active period of the external trigger is 10 pixel clocks (250ns)
FIGURE 68. PWC PIV Timing Table.
TABLE 9. Asynchronous Mode Chart
Asyn No Shutter Async Preset and Prog. Shutter PWC
aA <1 line <1 line 6 clk
aB 9.5 line (n+1) lines + 1024 clk Pulse width + 1024 clk
aC 1024 clk
Asyn No Shutter Async Preset and Prog. Shutter PWC
aA <1 line <1 line 6 clk
aB 9.5 line (n+1) lines + 1024 clk Pulse width + 1024 clk
aC 1024 clk
PIV Fixe Expo PIV PWC Unit
pA 6 6
pB 200 200
pC 160 160 Pixel
pD 320 320
pE 20 20
pF 1 1 Frame
Page view 79
1 2 ... 75 76 77 78 79 80 81 82 83 84 85 ... 91 92

Comments to this Manuals

No comments